Med Aire Low Air Loss Mattress Replacement System with Alarm
Features
- 3-Air cells remain static to enhance patient comfort
- 8 – LPM (Liters per Minute) pump produces consistent air flow
- 8″ cells are constructed with Nylon/TPU that is soft and lightweight
- CPR valves provide fast (20-Second) deflation
- Cell-on-Cell design prevents the patient from “Bottoming Out” in the event of a power failure
- Easy to replace individual bladders
- Ideal for use in hospitals, nursing homes and home care
- LED and Audible alarm activate when pressure falls below 10 mmHg
- Mattress has 20 air bladders, 9 with laser hose to achieve low air los function helping to keep the patient cool and speed recovery
- Mattress operates in an alternating pressure mode
- The product is designed to be used in the prevention, treatment and management of Pressure Ulcers
- The zippered Nylon TPU cover material is water resistant, vapor permeable and quilted
The Med-Aire Low Air Loss Alternating Pressure Mattress Replacement System by Drive Medical is designed to be used in the prevention, treatment and management of Pressure Ulcers. The mattress operates in an alternating pressure mode and is ideal for use in hospitals, nursing homes and home care. The individuals bladders are easy to remove and replace and the 3-Air cells remain static to enhance patient comfort. LED and Audible alarms activate when the pressure falls below 10 mmHg. and the Cell-on-Cell design prevents the patient from “Bottoming Out” in the event of a power failure, ensuring their safety and comfort. The 8 – LPM (Liters per Minute) pump produces consistent air flow. This mattress has 20 air bladders, 9 with laser hose to achieve low air loss function helping to keep the patient cool and speed recovery. The 8″ cells are constructed with Nylon/TPU that is soft and lightweight, providing comfort to all users. The zippered Nylon TPU cover material is water resistant, vapor permeable and quilted, making it ideal for hospital use. The CPR valves provide fast (20-Second) deflation.
Specifications
| Control Unit Airflow | 8 LPM |
|---|---|
| Control Unit Cycle Time | 10, 15, 20, 25 Minutes |
| Control Unit Type | Compressor |
| Control Unit Alarms | Visual / Audible |
| Mattress Cover Material | Fluid-Resistant Stretch |
| Weight Capacity | 450 lbs. |
| Warranty | 18 Month Limited |
Products
| Item # | Product Description | Product Dimensions | UOM |
|---|---|---|---|
| 14029 | Alternating Pressure/Low Air Loss Mattress System | 36″ (W) X 80″ (L) X 8″ (H) | 1/ea |
| 14029-84 | Alternating Pressure/Low Air Loss Mattress System | 36″ (W) X 84″ (L) X 8″ (H) | 1/ea |
Parts
| Diagram Number | Part Description | Part Number |
|---|---|---|
| 14029MN | ||
| 14029C | ||
| 14029-base | ||
| 14029-CELL | ||
| 14029-cell1 | ||
| 14001-l | ||
| 14001-t | ||
| 14029-fftc | ||
| 14029-fmtc | ||
| 14028v | ||
| 14013 | ||
| 14028t | ||
| 14029XP | ||
| 14030xp-s | ||
| 14007-3port | ||
| 14007or-3 | ||
| 14030hk | ||
| 14029fn | ||
| 14029xp-fc | ||
| 14530f | ||
| Power cord | 15005PC | |
| 14029b |
Order Now!
[gravityform id=”1″ title=”false” description=”false”]
Related products
10″ True Low Air Loss Mattress System with Pulsation
Features
- 2" convoluted foam base in case of power outage
- CPR feature allows for rapid deflation of mattress system Static function can suspend the pulsate mode
- For use in the Homecare, Long Term Care, and AcuteCare Markets
- The 10 Adjustable Comfort Settings allows pressure to be customized by patient's weight The Auto-Firm feature allows for a 1 minute fill rate
- The Masonair? LS9000 system offers an extraordinary therapeutic mattress system for the prevention and treatment of pressure ulcers
- The Powerloft Pro 900 pump produces 1180 liters of air flow per minute offering a cool and dry sleeping surface
- The exclusive Pulsate mode reduces the air flow every30 seconds to 50% of the comfort setting
- The internal pressure control sensor continuously monitors surface pressure for optimal pressure redistribution
- This feature will intermittently reduce pressure and increase blood flow
- Visible and audible alarms with Alarm Mute feature(3 minute auto-return feature) CPR valve allows for rapid deflation
Masonair 8″ Alternating Pressure and Low Air Loss Mattress System
Features
- Alternating Pressure Mode has 10, 15, 20, 25 minute cycle times
- Auto-Firm feature for max inflation when transferring patient and has auto-recovery after 30 minutes
- CPR valve allows for rapid deflation
- In case of a power failure the bottom 4" air cell will remain inflated offering sufficient weight support for the patient
- Lockout feature protects patient settings
- Pillow Top feature keeps head and neck stable
- Seat Inflation mode offers additional support when head of bed is raised for an extended period of time
- Static Mode can suspend alternating mode and has auto-recovery after 30 minutes
- The 10 adjustable comfort settings allows pressure to be customized by patient weight
- The Masonair? AS8800 Alternating Pressure Mattress with Low Air Loss is one of the most advanced systems in the Masonair? series
- The mattress consists of (20) 8" high cell-on-cell designed air bladders
- The microprocessor sensor technology provides continuous feedback to equalize pressure and maximize patient comfort
- Visible and audible alarms with Alarm Mute feature (3minute auto-return feature)
Med-Aire Assure 5″ Air + 3″ Foam Base Alternating Pressure and Low Air Loss Mattress System
Product Summary
- This combination therapy mattress system provides both alternating pressure and low air loss to optimize pressure redistribution and manage skin maceration
- Designed to prevent, treat and manage pressure ulcers in the home or long term care setting
- The Med-Aire Assure 14530 incorporates a system of (17) 5" individual bladders over a 3" foam base for power outage protection
- The pump offers a static feature as well as adjustable comfort settings by patient weight
- The removable cover is quilted for comfort, low shear, anti-microbial, water-resistant and vapor permeable
- CPR valve allows for rapid deflation
Premium Guard Gel Overlay
Product Summary
- Best in class gel overlay optimizes pressure redistribution and is now available in up to 500 lbs weight capacity
- 15 gel bladders cover entire patient contact area for the prevention and treatment of pressure ulcers
- Full length “head-to-toe” gel bladders minimize “bottoming out” and “pitting”
- New convoluted foam topper vastly improves patient comfort and air circulation
- 4 elastic corner straps secure overlay to mattress
- Urethane coated nylon cover is water resistant and vapor permeable
- Vinyl base is stain resistant and waterproof
- Bladders contain an aqueous non-toxic gel and polystyrene beads to minimize gel migration
ShearCare 1100 3 Layer Memory Foam Pressure Redistribution Foam Mattress
Features
- Bottom layer of high density foam provides a firm foundation
- Designated head and foot sections prevent installation errors
- Meets Federal Fire Code CFR 16 part 1633
- Multi-layered pressure redistribution foam mattress with a top layer of Memory-III? Visco Elastic, an all virgin self molding and shock-absorbing foam which contours tithe body offering reduced interface pressure readings
- The unique Uni-heel? section, is a one-piece die-cut high-resilient, low ILD foam offering maximum pressure relief in the vulnerable heel section
- This combination creates a superior pressure redistributing sleep system
- Top Cover is a 2-way stretch nylon which reduces heat buildup and provides a low-shear surface that is antimicrobial and water-resistant Concealed zipper and a Barrier Stop Over-Flap prevents liquids from contaminating mattress core
- Unique SSPT Rail System? provides solid-edge support, facilitating safe patient transfers
ShearCare 500 Pressure Redistribution Foam Mattress
Features
- A pressure redistribution foam mattress specifically created for facilities with limited budgets without sacrificing the clinical efficacy of more expensive surfaces
- Concealed zipper and a Barrier Stop Over-Flap prevents liquids from contaminating mattress core
- Designated head and foot sections prevent installation errors
- Meets Federal Fire Code CFR 16 part 1633
- Superior pressure redistribution is achieved by varying cell depths throughout the mattress zones
- This design allows for maximum immersion and envelopment
- This three-zoned mattress is comprised of 670independent cells
- Top Cover is a 2-way stretch nylon which reduces heat buildup and provides a low shear surface that is antimicrobial and water-resistant
- Unique SSPT Rail System? provides solid-edge support, allowing easy patient transfer to and from bed